ANDLOG_f

Logical and

Block Screenshot

Description

This block, with two event inputs and a regular output, outputs +1 or -1 on its regular output depending on input events.

  • +1 : When events are synchronously (present on both event input ports),
  • -1 : When only one event is present.

Default properties

  • always active: no
  • direct-feedthrough: no
  • zero-crossing: no
  • mode: no
  • regular outputs: - port 1 : size [1,1] / type 1
  • number/sizes of activation inputs: 2
  • number/sizes of activation outputs: 0
  • continuous-time state: no
  • discrete-time state: no
  • object discrete-time state: no
  • name of computational function: andlog

Interfacing function

  • SCI/modules/scicos_blocks/macros/Events/ANDLOG_f.sci

Table Of Contents