CLKOUTV_f

Output activation port

Block Screenshot

Description

This block represent an activation output port. It must only be used inside a Xcos Super Blockand be connected to an activation output on an internal activation output in the subsystem.

This block is an event link from outside of a system into a sub- system. In a Super Block, the activation’s output ports must be numbered from 1 to the total number of activation’s output ports. You can set it with the Port number parameter.

Dialog box

  • Port number An integer defining the port number. Properties : Type ‘vec’ of size 1.

Default properties

  • always active: no
  • direct-feedthrough: no
  • zero-crossing: no
  • mode: no
  • number/sizes of activation inputs: 1
  • number/sizes of activation outputs: 0
  • continuous-time state: no
  • discrete-time state: no
  • object discrete-time state: no
  • name of computational function: output

Example

The Super bloc below is mainly a frequency divider by 4, associated to an one event generation at time * `t= 3 s`* . `Open this example in Xcos`_ :

See also